Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.622
Filtrar
1.
Clin Biomech (Bristol, Avon) ; 114: 106239, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38599132

RESUMO

BACKGROUND: The application of expandable titanium-cages has gained widespread use in vertebral body replacement for indications such as burst fractures, tumors and infectious destruction. However, torque forces necessary for a satisfactory expansion of these implants and for subsidence of them into the adjacent vertebrae are unknown within the osteoporotic spine. METHODS: Six fresh-frozen human, osteoporotic, lumbar spines were dorsally instrumented with titanium implants (L2-L4) and a partial corpectomy of L3 was performed. An expandable titanium-cage was inserted ventrally and expanded by both residents and senior surgeons until fixation was deemed sufficient, based on haptic feedback. Torque forces for expansion were measured in Nm. Expansion was then continued until cage subsidence occurred. Torque forces necessary for subsidence were recorded. Strain of the dorsal rods during expansion was measured with strain gauges. FINDINGS: The mean torque force for fixation of cages was 1.17 Nm (0.9 Nm for residents, 1.4 Nm for senior surgeons, p = .06). The mean torque force for subsidence of cages was 3.1 Nm (p = .005). Mean peak strain of the dorsal rods was 970 µm/m during expansion and 1792 µm/m at subsidence of cages (p = .004). INTERPRETATION: The use of expandable titanium-cages for vertebral body replacement seems to be a primarily safe procedure even within the osteoporotic spine as torque forces required for subsidence of cages are nearly three times higher than those needed for fixation. Most of the expansion load is absorbed by straining of the dorsal instrumentation. Rod materials other than titanium may alter the torque forces found in this study.


Assuntos
Fusão Vertebral , Titânio , Humanos , Corpo Vertebral , Torque , Vértebras Lombares/cirurgia , Próteses e Implantes
2.
J Oral Implantol ; 50(1): 45-49, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579112

RESUMO

The stability of implant-abutment joint is fundamental for the long-term success of implant rehabilitation. The screw loosening, fracture, and head deformation are among the most common mechanical complications. Several surface treatments of titanium screws have been proposed to improve their resistance and stability. Diamond-like carbon (DLC) coating of the materials is widely used to increase their wear resistance and durability. The present study aimed to evaluate the effect of carbon fiber coating on the screw head on screw removal torque and screw head stripping. One hundred titanium implant screws were used, 50 without coating (Group 1) and 50 with DLC coating of the screw head (Group 2). Each screw was tightened with a torque of 25 Ncm and unscrewed 10 times. The removal torque was measured with a digital cap torque tester for each loosening. Optical 3d measurement of the screw head surface was performed by a fully automatic machine before and after multiple tightening to investigate surface modifications. The reverse torque values decreased with repeated tightening and loosening cycles in both groups without significant differences (P > .05). Optical measurements of surface dimensions revealed average changes of 0.0357 mm in Group 1 and 0.02312 mm in Group 2, which resulted to be statistically significant (P < .001). The DLC coating of the retention screw head can prevent its distortion and wear, especially after multiple tightening.


Assuntos
Implantes Dentários , Carbono , Titânio , Análise do Estresse Dentário/métodos , Torque , Parafusos Ósseos , Dente Suporte
3.
J Oral Implantol ; 50(1): 31-38, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579114

RESUMO

The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.


Assuntos
Implantes Dentários , Torque , Dente Suporte , Análise do Estresse Dentário , Retenção em Prótese Dentária , Projeto do Implante Dentário-Pivô
4.
J Mech Behav Biomed Mater ; 154: 106537, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38588632

RESUMO

The Advanced System for Implant Stability Testing (ASIST) is a device currently being developed to noninvasively measure implant stability by estimating the mechanical stiffness of the bone-implant interface, which is reported as the ASIST Stability Coefficient (ASC). This study's purpose was to determine whether changes in density, bonding, and drilling technique affect the measured vibration of a dental implant, and whether they can be quantified as a change in the estimated BII stiffness. Stability was also measured using RFA, insertion torque (IT) and the pullout test. Bone-level tapered implants (4.1 mm diameter, 10 mm length) were inserted in polyurethane foam as an artificial bone substitute. Samples were prepared using different bone densities (20, 30, 40 PCF), drilling sequences, and superglue to simulate a bonded implant. Measurements were compared across groups at a significance level of 0.05. The ASC was able to indicate changes in each factor as a change in the interfacial stiffness. IT and pullout force values also showed comparable increases. Furthermore, the relative difference in ISQ values between experimental groups was considerably smaller than the ASC. While future work should be done using biological bone and in-vivo systems, the results of this in-vitro study suggest that modelling of the implant system with a vibration-based approach may provide a noninvasive method of assessing the mechanical stability of the implant.


Assuntos
Substitutos Ósseos , Implantes Dentários , Vibração , Osso e Ossos , Densidade Óssea , Torque
5.
PLoS One ; 19(4): e0296300, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635518

RESUMO

OBJECTIVE: This study aimed to compare the stability and mechanical properties of the double chevron-cut (DCC) and biplanar (BP) distal femoral osteotomy (DFO) techniques, along with analyzing their respective contact surface areas. METHODS: Biomechanical testing was performed using sawbone and 3D modeling techniques to assess axial and torsional stability, torsional stiffness, and maximum torque of both osteotomy configurations. Additionally, 3D models of the sawbone femur were created to calculate and compare the contact surface area of the DCC, BP, and conventional single-plane DFO techniques. RESULTS: Axial stiffness and maximum strength did not significantly differ between the two osteotomy techniques. However, in terms of torsional properties, the DCC technique exhibited superior torsional stiffness compared to the BP group (27 ± 7.7 Nm/° vs. 4.5 ± 1.5 Nm/°, p = 0.008). Although the difference in maximum torque did not reach statistical significance (63 ± 10.6 vs. 56 ± 12.1, p = 0.87), it is noteworthy that the DCC group sawbone model exhibited fracture in the shaft region instead of at the osteotomy site. Therefore, the actual maximum torque of the DCC construct may not be accurately reflected by the numerical values obtained in this study. The contact surface area analysis revealed that the BP configuration had the largest contact surface area, 111% larger than that of the single-plane configuration. but 60% of it relied on the less reliable axial cut. Conversely, the DCC osteotomy offered a 31% larger contact surface area than the single-plane configuration, with both surfaces being weight-bearing. CONCLUSION: The DCC osteotomy exhibited superior mechanical stability, showing improved rotational stiffness and maximum torque when compared to the BP osteotomy. Although the BP osteotomy resulted in a larger contact surface area than the DCC osteotomy, both were larger than the conventional single-plane configuration. In clinical practice, both the DCC and BP techniques should be evaluated based on patient-specific characteristics and surgical goals.


Assuntos
Fraturas Ósseas , Osteotomia , Humanos , Osteotomia/métodos , Fêmur/cirurgia , Torque , Extremidade Inferior , Fenômenos Biomecânicos
6.
Int J Oral Maxillofac Implants ; 39(2): 271-277, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657219

RESUMO

PURPOSE: To investigate the relationship between the structural parameters of trabecular bone obtained from CBCT imaging and the primary stability of dental implants. MATERIALS AND METHODS: Sixty patients underwent implant placement followed by primary stability evaluation via measurement of the insertion torque (IT) and the implant stability quotient (ISQ). Gray values (GV) and the fractal dimension (FD) were also measured using pretreatment CBCT images. RESULTS: FD values showed a positive and significant relationship with ISQ and IT values (P = .017 and P = .004, respectively). Additionally, there was a positive and significant correlation between GV and IT (P = .004) as well as between GV and ISQ (P = .010). FD and GV showed a considerable difference between the maxillary and mandibular jaws and were higher in the mandible. Only FD was significantly different between men and women and was higher in men. In the two age groups (older and younger than 45 years), only GV was considerably higher in people older than 45 (P < .05). CONCLUSIONS: Both fractal dimension and gray values obtained from CBCT are efficient methods for predicting the primary stability of the implant due to their relationship with ISQ and IT values.


Assuntos
Osso Esponjoso , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Fractais , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Osso Esponjoso/diagnóstico por imagem , Implantação Dentária Endóssea/métodos , Torque , Idoso , Retenção em Prótese Dentária , Mandíbula/diagnóstico por imagem
7.
BMC Oral Health ; 24(1): 486, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654276

RESUMO

INTRODUCTION: This study utilizes investigate the impact of posterior torques on the three-dimensional force exerted on the lower anterior teeth during the retraction in orthodontic clear aligners treatment. METHODS: Four groups of mandibular dental arch light-cured resin models will be created, including: mandibular posterior teeth with standard torque, mandibular posterior teeth with labial torque, and mandibular posterior teeth with lingual torque. Each group will consist of 12 sets of clear aligners. The aligners will be worn, and measurements will be taken using the six-axis measurement platform to evaluate the three-dimensional force exerted on the lower anterior teeth under various initial torques applied to the mandibular posterior teeth. SPSS 26.0 used for ANOVA analysis, α = 0.05 significance level. RESULTS: Comparing mandibular posterior teeth with standard torque to those with labial torque, no statistically significant changes were observed in buccolingual force. In the mesiodistal direction, mandibular incisors exhibited a significant decrease in distal force, while canines showed a significant increase. Both findings had a significance level of P < 0.05; Lingual torque on mandibular posterior teeth, compared to standard torque, led to a significant increase in lingual force for incisors and a significant increase in labial force for canines in the buccolingual direction (P < 0.05). Additionally, mandibular incisors exhibited a significant decrease in distal force in the mesiodistal direction (P < 0.05). CONCLUSION: Varying initial torques on mandibular posterior teeth significantly impact force on lower anterior teeth. Labial torque reduces lingual force on incisors and increases distal force on canines. Lingual torque increases lingual force on incisors and labial force on canines.


Assuntos
Incisivo , Técnicas de Movimentação Dentária , Torque , Humanos , Técnicas de Movimentação Dentária/métodos , Técnicas de Movimentação Dentária/instrumentação , Técnicas In Vitro , Dente Canino , Mandíbula , Fenômenos Biomecânicos , Análise do Estresse Dentário , Modelos Dentários , Aparelhos Ortodônticos Removíveis
8.
BMC Oral Health ; 24(1): 389, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532413

RESUMO

BACKGROUND: While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS: One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS: The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS: One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.


Assuntos
Coroas , Cimentos Dentários , Zircônio , Humanos , Torque , Teste de Materiais , Dente Suporte , Titânio , Parafusos Ósseos , Análise do Estresse Dentário , Falha de Restauração Dentária
9.
Clin Oral Investig ; 28(3): 206, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459220

RESUMO

OBJECTIVES: This finite element study aimed to simulate maxillary canine movement during anterior teeth retraction. MATERIALS AND METHODS: Three methods of maxillary canine movement including miniscrew sliding with high hooks (MSH), miniscrew sliding with low hooks (MSL), and the traditional sliding method (TS) without using miniscrews were simulated using three-dimensional finite element analysis. The initial displacement of the maxillary canine, the maximum principal stress of the periodontal ligament and the Von Mises stress were calculated. RESULTS: The distolingual tipping movements of the canine were shown in three movement modes. MSH showed a small tendency to lingual tipping movement and a extrusion movement while MSL had the largest lingual inclination. TS demonstrated a tendency toward distolingual torsion displacement. Compressive stress values were mainly concentrated in the range - 0.003 to -0.006 MPa. For tensile stress, the distribution of MSH and MSL was concentrated in the range 0.005 to 0.009 MPa, TS was mainly distributed about 0.003 MPa. Von Mises equivalent stress distribution showed no significant difference. CONCLUSIONS: The loss of tooth torque was inevitable, irrespective of which method was used to close the extraction space. However, miniscrew application and higher hooks reduced the loss of torque and avoided lingual rotation. CLINICAL RELEVANCE: This study shows that miniscrew implants with different hooks can better control the movement of the maxillary canines. The non-invasive nature of the finite element analysis and its good simulation of dental stress and instantaneous motion trend have a clinical advantage in the analysis of tooth movement.


Assuntos
Dente Canino , Técnicas de Movimentação Dentária , Dente Pré-Molar , Estresse Mecânico , Análise de Elementos Finitos , Torque , Técnicas de Movimentação Dentária/métodos , Maxila
10.
J Musculoskelet Neuronal Interact ; 24(1): 38-46, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38427367

RESUMO

BFR) applied during sprint interval training (SIT) on performance and neuromuscular function. METHODS: Fifteen men completed a randomized bout of SIT with CBFR, IBFR, and without BFR (No-BFR), consisting of 2, 30-s maximal sprints on a cycle ergometer with a resistance of 7.5% of body mass. Concentric peak torque (CPT), maximal voluntary isometric contraction (MVIC) torque, and muscle thickness (MT) were measured before and after SIT, including surface electromyography (sEMG) recorded during the strength assessments. Peak and mean revolutions per minute (RPM) were measured during SIT and power output was examined relative to physical working capacity at the fatigue threshold (PWCFT). RESULTS: CPT and MVIC torque decreased from pre-SIT (220.3±47.6 Nm and 355.1±72.5 Nm, respectively) to post-SIT (147.9±27.7 Nm and 252.2±45.5 Nm, respectively, all P<0.05), while MT increased (1.77±0.31 cm to 1.96±0.30 cm). sEMG mean power frequency decreased during CPT (-12.8±10.5%) and MVIC (-8.7±10.2%) muscle actions. %PWCFT was greater during No-BFR (414.2±121.9%) than CBFR (375.9±121.9%). CONCLUSION: SIT with or without BFR induced comparable alterations in neuromuscular fatigue and sprint performance across all conditions, without affecting neuromuscular function.


Assuntos
Treinamento Intervalado de Alta Intensidade , Músculo Esquelético , Humanos , Masculino , Eletromiografia , Contração Isométrica/fisiologia , Fadiga Muscular , Músculo Esquelético/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Torque
11.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544265

RESUMO

We aimed to determine the feasibility, test-retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load. To examine the test-retest reliability and long-term stability of torque-cadence values, the progressive test was repeated after 72 h and also after 10 weeks of aerobic and strength training. The participants' MDF averaged 13.4 ± 1.3 N·kg-1, which was attained with an average pedal cadence of 21 ± 3 rpm. Participants' highest power output value was attained with a cadence of 110 ± 16 rpm (52 ± 5% MDF). The relationship between the MDF and cadence proved to be very strong (R2 = 0.978) and independent of the cyclists' MDF (p = 0.66). Cadence values derived from this relationship revealed a very high test-retest repeatability (mean SEM = 4 rpm, 3.3%) and long-term stability (SEM = 3 rpm, 2.3%); despite increases in the MDF following the 10-week period. Our findings support the validity, reliability and long-term stability of this method for the assessment of the torque-cadence profile and MDF in cyclists.


Assuntos
Ciclismo , Ergometria , Humanos , Masculino , Torque , Reprodutibilidade dos Testes , , Teste de Esforço/métodos
12.
Braz Dent J ; 35: e245599, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537013

RESUMO

The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.


Assuntos
Implantes Dentários , Brasil , Torque , Implantação Dentária Endóssea
13.
Braz Dent J ; 35: e245632, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537016

RESUMO

This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values ​​at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values ​​in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.


Assuntos
Implantes Dentários , Humanos , Planejamento de Prótese Dentária , Boca , Face , Torque , Implantação Dentária Endóssea/métodos
14.
Sci Rep ; 14(1): 7525, 2024 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553519

RESUMO

The paper deals with the torques of external muscles acting on the upper ankle joint under weight-bearing conditions and their importance in diagnosing and treating the human foot. Experimental data were collected and calculations were performed. Based on the experiments with the biomechanical model of the foot and upper ankle joint, it was shown how the changes in the force arms of the external muscles of the foot under weight-bearing conditions, change the torque. The real values of muscle forces and torques of the external muscles of the foot were calculated. Taking into account the distance of the lines of muscle action from the axis of rotation of the upper ankle joint the rotational force of the muscles was calculated. The influence of changing the force arm on the rotational efficiency of the muscle balancing the moment of gravity was shown. Knowledge of muscle torque under weight-bearing conditions is crucial for correctly assessing foot biomechanics. It has been shown that torque (gravitational and muscular), not pure force, is crucial when assessing the rotational capacity of the analyzed joint. A change in the approach to diagnostics and treating paresis or weakness of extrinsic foot muscles was proposed through the manipulation of the distance of their action line from the axis of joint rotation.


Assuntos
Articulação do Tornozelo , Ossos do Tarso , Humanos , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/fisiologia , Torque , Músculo Esquelético/fisiologia , Pé/fisiologia , Fenômenos Biomecânicos
17.
J Biomech Eng ; 146(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38470378

RESUMO

Muscle torque generators (MTGs) have been developed as an alternative to muscle-force models, reducing the muscle-force model complexity to a single torque at the joint. Current MTGs can only be applied to single Degree-of-freedom (DoF) joints, leading to complications in modeling joints with multiple-DoFs such as the shoulder. This study aimed to develop an MTG model that accounts for the coupling between 2-DoF at the shoulder joint: shoulder plane of elevation (horizontal abduction/adduction) and shoulder elevation (flexion/extension). Three different 2-DoF MTG equations were developed to model the coupling between these two movements. Net joint torques at the shoulder were determined for 20 participants (10 females and 10 males) in isometric, isokinetic, and passive tests. Curve and surface polynomial fitting were used to find the best general fit for the experimental data in terms of the different degrees of coupling. The models were validated against experimental isokinetic torque data. It was determined that implicit coupling that used interpolation between single-DoF MTGs resulted in the lowest root-mean-square percent error of 8.5%. The work demonstrated that general MTG models can predict torque results that are dependent on multiple-DoFs of the shoulder.


Assuntos
Articulação do Ombro , Masculino , Feminino , Humanos , Articulação do Ombro/fisiologia , Torque , Ombro , Músculos , Movimento/fisiologia , Fenômenos Biomecânicos
18.
J Appl Physiol (1985) ; 136(4): 889-900, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38450425

RESUMO

Resistance training at longer muscle lengths induces greater muscle hypertrophy and different neuromuscular functional adaptations than training at shorter muscle lengths. However, the acute time course of recovery of neuromuscular characteristics after resistance exercise at shorter and longer muscle lengths in the quadriceps has never been described. Eight healthy young participants (4 M, 4 F) were randomly assigned to perform four sets of eight maximal isometric contractions at shorter (SL; 50° knee flexion) or longer (LL; 90° knee flexion) muscle lengths in a crossover fashion. During exercise, peak torque (PT), muscle activity [electromyogram (EMG)], and internal muscle forces were assessed. PT and EMG at shorter (PT50, EMG50) and longer (PT90, EMG90) muscle lengths, creatine kinase (CK), and muscle soreness were measured at baseline, immediately after exercise (Post), after 24 h (24 h), and after 48 h (48 h). During exercise, EMG (P = 0.002) and internal muscle forces (P = 0.017) were greater in LL than in SL. During recovery, there was a main effect of exercise angle, with PT50 (P = 0.002), PT90 (P = 0.016), and EMG50 (P = 0.002) all significantly reduced to a greater degree in LL compared with SL. CK and muscle soreness increased after resistance exercise, but there were no differences between SL and LL. The present results suggest that if the preceding isometric resistance exercise is performed at longer muscle lengths, function and muscle activity at shorter and longer muscle lengths are inhibited to a larger degree in the subsequent recovery period. This information can be used by practitioners to manipulate exercise prescription.NEW & NOTEWORTHY Despite the established long-term benefits of training at longer muscle lengths for muscle size and strength, acutely performing resistance exercise at longer muscle lengths may require a longer time course of neuromuscular recovery compared with performing resistance exercises at shorter muscle lengths. Furthermore, there appear to be different joint angle-specific recovery profiles, depending on the muscle length of the preceding exercise.


Assuntos
Músculo Esquelético , Treinamento de Força , Humanos , Músculo Esquelético/fisiologia , Treinamento de Força/métodos , Mialgia , Eletromiografia , Músculo Quadríceps , Contração Isométrica/fisiologia , Creatina Quinase , Torque
19.
PLoS One ; 19(3): e0298401, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38512896

RESUMO

Researchers conducted an investigation by tornado simulator to study the impact of wind angle on the aerodynamic characteristics of a reduced (1:150) high-speed train model using six-dimensional force/torque sensor. The reduced scale model size can match the relative size relationship between high-speed train and tornado vortex core in real condition. Results show that the wind angle affects the mean value and standard deviation of the force and moment coefficient of the high-speed train at the same radial position. The variations of the mean value and standard deviation of the pitching moment coefficient of the high-speed train carriage model at 60°and 90°are different from that at other wind angles. The variations of the mean value of the pitching moment coefficient of the high-speed train head model at 0°, 15°and 30°are different from that at other wind angles. The variations of the standard deviation of the pitching moment coefficient of the high-speed train head model at 60°,75°and 90°are different from that at other wind angles. This research will help the further study of the operation safety of high-speed train in the event of a tornado impacting a high-speed train network.


Assuntos
Tornados , Vento , Torque
20.
Sensors (Basel) ; 24(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38475041

RESUMO

The choice of torque curve in lower-limb enhanced exoskeleton robots is a key problem in the control of lower-limb exoskeleton robots. As a human-machine coupled system, mapping from sensor data to joint torque is complex and non-linear, making it difficult to accurately model using mathematical tools. In this research study, the knee torque data of an exoskeleton robot climbing up stairs were obtained using an optical motion-capture system and three-dimensional force-measuring tables, and the inertial measurement unit (IMU) data of the lower limbs of the exoskeleton robot were simultaneously collected. Nonlinear approximations can be learned using machine learning methods. In this research study, a multivariate network model combining CNN and LSTM was used for nonlinear regression forecasting, and a knee joint torque-control model was obtained. Due to delays in mechanical transmission, communication, and the bottom controller, the actual torque curve will lag behind the theoretical curve. In order to compensate for these delays, different time shifts of the torque curve were carried out in the model-training stage to produce different control models. The above model was applied to a lightweight knee exoskeleton robot. The performance of the exoskeleton robot was evaluated using surface electromyography (sEMG) experiments, and the effects of different time-shifting parameters on the performance were compared. During testing, the sEMG activity of the rectus femoris (RF) decreased by 20.87%, while the sEMG activity of the vastus medialis (VM) increased by 17.45%. The experimental results verify the effectiveness of this control model in assisting knee joints in climbing up stairs.


Assuntos
Exoesqueleto Energizado , Robótica , Humanos , Torque , Extremidade Inferior , Articulação do Joelho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...